Chapter 3
Troubleshooting
Table 3-1
Common Problems and Solutions (continued)
Symptom
System LED is amber
Switch placed in
error-disabled state after
GBIC module is inserted
78-11157-03
Possible Cause
Internal fan fault detected.
Nonfatal or fatal POST error
detected.
Bad or non-Cisco-approved GBIC
module.
Catalyst 2950 Desktop Switch Hardware Installation Guide
Diagnosing Problems
Resolution
Check if the fan has failed
by using the show env fan
privileged EXEC command.
If the fan has failed, call
Cisco Systems.
Use the show post
privileged EXEC command
to see which POST test
failed.
Remove GBIC module from the
switch, and replace it with a
Cisco-approved module. Use the
errdisable recovery cause
gbic-invalid global
configuration command to
verify port status, and enter a
time interval to recover from the
error-disable state.
Refer to the switch software
configuration guide for
information about the
errdisable recovery command.