Chapter 6
Troubleshooting
Table 6-3
System Error and Recovery Messages
LED Type
LED Color

Recovering a Lost Password

You can recover a lost enable password. However, an enable secret password is encrypted and is not
recoverable. If you lose an enable secret password that is configured on your router, you can replace it
with a new enable secret password.
For password recovery and replacement procedures for the Cisco 1800 series fixed-configuration
routers, see the
More Troubleshooting Help—Cisco Technical Assistance
Center
For online troubleshooting help, go to the
You must have an account on Cisco.com. If you do not have an account or have forgotten your username
or password, click Cancel at the login dialog box and follow the instructions that appear.
OL-6425-03
Message, Meaning, and Recommended Action
Error:
%ENVMON-3-FAN_FAILED: Fan not rotating.
Explanation:
The fan is not rotating at the desired speed.
Recovery:
Make sure that the fan power cable is properly attached to the system board fan power
connector. If the problem persists, contact your technical support representative.
Message:
%ENVMON-1-NO_PROCESS: Failed to create environmental monitor process
Explanation:
The router failed to establish the environmental monitor process. The amount of memory
available in the router may not be sufficient.
Recommended action:
Increase the amount of memory (RAM) in the router.