4. Approximately 20 seconds after the Ethernet Cable has been disconnected, the Analyzer will recognize that it
has lost communications with the DAq and activate the "Manual Override" button. The LED's on the front of
the Analyzer will flash to show a Maintenance Fault per the LED status flash pattern.
To reset faults and alarms press and hold button for 1-3 seconds.
To Exit Monitor and Open Gate press and hold button for 10 seconds and above.
To restart monitoring mode, press and hold button for 4 to 9 seconds.
5. Close and reattach the Analyzer cover, reconnect the Ethernet Communications Cable and slide the Analyzer
into the cabinet.