Mechanical installation

The mechanical installation is divided into the following sub-chapters:
Installation of 764/767/361/MRT temperature probe (section 2.2)
Installation of 765 water probe, 766/768/365 Combi probe (section 2.3)
Installation of 762 VITO Interface (section 2.5)
The VITO Interface and probe may be installed in hazardous areas.
Before starting installation, check whether the actual area of installation complies with the
area classification on the applicable approval certificate for your type of VITO Interface.
Notes:
The entire installation procedure shall be in accordance with national, local and
company regulations.
2.1

Recommended tools

Following tools are recommended for installation of the VITO Interface and probe:
Spanners, size 32 mm (1" 4/16) and 36 mm (1" 7/16)
Allen keys, size 4 mm (5/32") and 2.5 mm (3/32")
Pair of wire cutters
Flat head screw driver, 2 – 3 mm (2/16")
Wire stripper
Teflon tape / pipe sealant
Tie-wraps
2.2

Mechanical installation of 764/767/361/MRT temperature probe

The 764/767/361/MRT temperature probe can be installed in two ways:
2.2.1

Installation in a vertical thermowell

Minimal, a 2" thermowell must be used. The thermowell flange must be provided with a
G ½ (½" BSP) threaded opening and an earth screw for connection of the probe.
Preferably the thermowell should be perforated (holes or slots).
However, closed thermowells are a must for pressurized applications, and are
recommended for applications where aggressive products are stored.
Although it is not recommended, closed thermowells can be liquid filled for better heat
transfer between the stored product and VITO probe. Normal lube oil can be used, but
also glycol.
Care must be taken when the tank contains edible products in order to prevent product
contamination in the event of thermowell failure.
in an open or closed vertical thermowell or
directly in the tank (using anchor weights)