iring diagram
Mount field paying attention to the following matters.
1. Poke in terminal side has to be
faced to armature fan side.
2. Orange lead wire side has to be
located on switch side.
Poke in terminals
Orange
lead wire
Pass the field lead wires along the
wall of motor housing.
The lead wire of tab terminal
has to be put in the space between
rib and wall of motor housing.
Do not put on the rib.
Handle cover
Sponge sheet
Put sponge sheet
into the illustrated
position
Switch
Wall of
motor housing
Rib
Tab terminal
Line coil
if it is used.
Noise
suppressor,
if any.
Rib
Insulation cover
Armature
Fig.A
Insulation covers have to be mounted as per Fig. A.
Do not mount them as per Fig. B.
Switch
P 11 / 11
Insulation cover
Armature
Fig.B
Insulation cover
Put the slack portion of
lead wires into the space
between field core and
the wall of motor housing.
Insulated
terminal
Put lead wires of power
supply cord on the right
side of rib.

Advertisement