Chapter 15
Performance Monitoring
Table 15-54 Near-End or Far-End OTN G.709 PM Parameters for TXP_MR_2.5G
Parameter
UAS-SM
FC-SM
ESR-SM
SESR-SM
BBER-SM
BBE-PM
ES-PM
SES-PM
UAS-PM
FC-PM
ESR-PM
SESR-PM
BBER-PM
April 2008
15.6.6 TXP_MR_2.5G and TXPP_MR_2.5G Card Performance Monitoring Parameters
and TXPP_MR_2.5G Cards (continued)
Definition
Section Monitoring Unavailable Seconds (UAS-SM) indicates the
unavailable seconds recorded in the OTN section during the PM time
interval.
Section Monitoring Failure Counts (FC-SM) indicates the failure counts
recorded in the OTN section during the PM time interval.
Section Monitoring Errored Seconds Ratio (ESR-SM) indicates the
errored seconds ratio recorded in the OTN section during the PM time
interval.
Section Monitoring Severely Errored Seconds Ratio (SESR-SM)
indicates the severely errored seconds ratio recorded in the OTN section
during the PM time interval.
Section Monitoring Background Block Errors Ratio (BBER-SM)
indicates the background block errors ratio recorded in the OTN section
during the PM time interval.
Path Monitoring Background Block Errors (BBE-PM) indicates the
number of background block errors recorded in the OTN path during the
PM time interval.
Path Monitoring Errored Seconds (ES-PM) indicates the errored seconds
recorded in the OTN path during the PM time interval.
Path Monitoring Severely Errored Seconds (SES-PM) indicates the
severely errored seconds recorded in the OTN path during the PM time
interval.
Path Monitoring Unavailable Seconds (UAS-PM) indicates the
unavailable seconds recorded in the OTN path during the PM time
interval.
Path Monitoring Failure Counts (FC-PM) indicates the failure counts
recorded in the OTN path during the PM time interval.
Path Monitoring Errored Seconds Ratio (ESR-PM) indicates the errored
seconds ratio recorded in the OTN path during the PM time interval.
Path Monitoring Severely Errored Seconds Ratio (SESR-PM) indicates
the severely errored seconds ratio recorded in the OTN path during the PM
time interval.
Path Monitoring Background Block Errors Ratio (BBER-PM) indicates
the background block errors ratio recorded in the OTN path during the PM
time interval.