Rule Number:
Max. 4 rules available.
Rule Switch:
Activate or inactivate the rule
1. Choose one of the
can set for PID function.
2. To enable the detection in
3. Choose a
Rule Type.
AB: Camera will only detect the action from side A to side B;
BA: Camera will only detect the action from side B to side A;
AB: Camera will detect the action from either side B to side A or side A to side B.
4. Use your mouse to click 4 points in the camera picture to draw a virtual region. The sharp
of the region should be a convex polygon. Concave polygon will be not able to save.
5. Click
Save
to save your settings.
6. If you want to modify the position or sharp of region, click the red box in the region, the
borders of the region will be changed to red color. Long press the left button of your
mouse to move the position of the region, or drag the corners to resize the region.
7. If you want to remove one of the regions from the camera picture, click the red box in the
region and then click
Notes:
1) The perimeter shall not be too close to the edges/corners of the camera picture, since it
may fail to trigger the detection when the target pass through the edges/corners.
2) The shape of the regions shall not be too narrow/small, since it may fail to trigger the
detection when the target passes through outside the perimeter.

5.1.9.1.1 Alarm Setup

Click
icon to configure alarm settings.
Rule
Number. It is the number of PID area. Maximum 4 areas you
Rule
Switch.
button. Click
Remove
will delete all regions.
Remove All
37