6.5
Technical data

6.5.1 Technical data 4G IP module

Nominal operating voltage
Operating voltage range
Power intake (max.)
Power intake for active transmis-
sion mode
2G
3G
4G
Output power depending on the
supported frequency band of the
RFW
Environmental class according to
VdS / EN 50131-3
Operation temperature range
Storage temperature range
Relative air humidity
Weight
Dimensions of PCB (W x H x T)
Conformity
12 V DC
10.5 V DC to 15 V DC
The total power intake (all USB ports plus 4G IP module)
must not exceed 1190 mA.
260 mA / with Ethernet 290 mA
170 mA / with Ethernet 200 mA
160 mA / with Ethernet 190 mA
Class 4 (+33dBm ±2dB) for EGSM900
Class 1 (+30dBm ±2dB) for GSM1800
Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK
Class 3 (+23.5dBm +1.5/-2,5dB) for UMTS 2100,WCDMA
FDD BdI
Class 3 (+23.5dBm +1.5/-2,5dB) for UMTS 900, WCDMA
FDD BdVIII
Class 3 (+23dBm +1dB/-2dB) for LTE 700, LTE FDD Bd28
Class 3 (+23dBm +1dB/-2dB) for LTE 800, LTE FDD Bd20
Class 3 (+23dBm +1dB/-2dB) for LTE 900, LTE FDD Bd8
Class 3 (+23dBm +1dB/-2dB) for LTE 1800, LTE FDD Bd3
Class 3 (+23dBm +1dB/-2dB) for LTE 2100, LTE FDD Bd1
II / Class II
-10°C to +55°C
-25°C to +70°C
max. 75% non-condensing
150 g
121 x 35 x 90
Module art. no. 057810 conforms to EN 50131-3, grade 3,
class II
EN50136: When using the 4G IP USB extension module
in conjunction with the MB Secure intrusion alarm panel,
EN50136-compliant message transmission of the alarm
transmission system category SP2 to SP6 / DP2 to DP4 is
enabled.