This manual provides critical safety instructions on the proper setup, operation, maintenance, and service of this machine/tool. Save this document, refer to it often, and use it to instruct other operators. Failure to read, understand and follow the instructions in this manual may result in fire or serious personal injury—including amputation, electrocution, or death.
The front of the cabinet is equipped with a large gas-assisted folding door for easy workpiece loading and unloading. Media can be quickly unloaded through the hopper dump port and reloaded through the loading door. Model G0714 (Mfd. Since 05/22)
C. DUST COLLECTOR ON/OFF Switch Dust Collector Dump Port D. LIGHT ON/OFF Switch K. Loading Door E. Filter Cleaning Plunger Foot Valve for Blast Gun Control Dust Collector M. Air Regulator w/Gauge G. LED Light Assembly N. Blasting Gloves Model G0714 (Mfd. Since 05/22)
Suggested.Operating.Air.Pressure.Range....................60.-.125.PSI Maximum.Air.Pressure............................125.PSI Recommended.Air.Supply..........................5.-.35.CFM Maximum.Abrasive.Capacity..........................250.lbs. Suggested.Abrasive.Capacity..........................55.lbs. Abrasive.Type..............................Dry.Only Load.&.Unload.Access.............................. Front Maximum.Load.Capacity............................132.lbs. Design.Type................................Floor Blast.Compartment.Door....................37-1/2.in..Wide.x.29-1/4.in..Tall. . Model G0714 (Mfd. Since 05/22) Model G0714 Page 1 of 2...
Page 7
Construction Information Body............................Welded.Heavy-Duty.Steel Paint.Type/Finish............................Powder.Coated Other Specifications: Country.of.Origin................................China Warranty.................................... 1.Year Serial.Number.Location..............................ID.Label Assembly.Time................................60.Minutes Features: Front-Loading.Door Natural.Rubber/Vinyl.Blast.Gloves Blast.Gun.Includes.4.Ceramic.Tips Perforated.Steel.Work.Table Powder.Coated.Inside.and.Out 12-Gauge.Steel.Legs.(16-Gauge.Panels) Extra-Rugged,.Heavy-Duty.Foot.Valve.Assembly Internal.LED.Lighting.System Model G0714 (Mfd. Since 05/22) Page 2 of 2 Model G0714...
Never operate under the influence of drugs or injury or blindness from flying particles. Everyday alcohol, when tired, or when distracted. eyeglasses are NOT approved safety glasses. Model G0714 (Mfd. Since 05/22)
Page 9
EXPERIENCING DIFFICULTIES. If at any time debris. Make sure they are properly installed, you experience difficulties performing the intend- undamaged, and working correctly BEFORE ed operation, stop using the machine! Contact our operating machine. Technical Support at (570) 546-9663. Model G0714 (Mfd. Since 05/22)
If normal safety pre- respect. Failure to do so could result in cautions are overlooked or ignored, seri- serious personal injury, damage to equip- ous personal injury may occur. ment, or poor work results. Model G0714 (Mfd. Since 05/22)
To reduce the risk of these hazards, avoid over- loading the machine during operation and make sure it is connected to a power supply circuit that meets the specified circuit requirements. Model G0714 (Mfd. Since 05/22)
Page 12
Two-prong outlets do not meet the grounding requirements for this machine. Do not modify or use an adapter on the plug provided—if it will not fit the outlet, have a qualified electrician install the proper outlet with a verified ground. -10- Model G0714 (Mfd. Since 05/22)
IMPORTANT: Save all packaging materials until weight of this machine. you are completely satisfied with the machine and have resolved any issues between Grizzly or the shipping agent. You MUST have the original pack- aging to file a freight claim. It is also extremely helpful if you need to return your machine later.
—Cabinet Screws M6-1 x 12 (Regulator) .. 2 ing or they are pre-installed at the factory. — Flange Nuts M6-1 (Regulator) ....2 —Cabinet Screws M6-1 x 12 (Dust Collector) ........4 — Flange Nuts M6-1 (Dust Collector) ..4 -12- Model G0714 (Mfd. Since 05/22)
Shadows, glare, or strobe effects that may distract access restricted location. or impede the operator must be eliminated. Wall Power 6" Min. Supply Supply Dust Collector Fresh Air Output Air Input 24" Min. 48" 12" Min. 53" Figure 4. Working clearances. -13- Model G0714 (Mfd. Since 05/22)
Anchor studs are stronger and more per- manent alternatives to lag shield anchors; however, they will stick out of the floor, which may cause a tripping hazard if you decide to move your machine. -14- Model G0714 (Mfd. Since 05/22)
DISCONNECT THE AIR SUPPLY BEFORE ADJUSTMENTS, MAINTENANCE, OR SERVICE. Two-Stage Air Compresssor Blast Cabinet Blast Gun Dedicated Media Blasting Blast Cabinet Air Dryer System Air Regulator Cabinet Hopper with Media Blast Cabinet Foot Valve -16- Model G0714 (Mfd. Since 05/22)
With one hand, grasp cabinet door handle. With other hand, unlatch door and let it open slowly, as shown in Figure 9. Cabinet Hopper Figure 7. Unpacking cabinet. Figure 9. Opening cabinet door. -17- Model G0714 (Mfd. Since 05/22)
Page 20
Figure 13. Aligning hopper with cabinet. blast cabinet mating surfaces. When items become aligned, they can slide together 10. Install remaining (16) M6-1 x 16 Phillips head without warning, causing a severe pinch screws with their flat washers. injury. -18- Model G0714 (Mfd. Since 05/22)
Page 21
Foot Valve Output Line Figure 17. Foot valve installation. 18. Locate dust collector canister assembly and Figure 15. Blast gun stowage. unlatch dust collector motor, lift dust collector out of canister, and set it aside. -19- Model G0714 (Mfd. Since 05/22)
Page 22
Figure 21 between suction port and hole in cabinet wall. Figure 21. Dust collector gap to be sealed. 24. Re-install baffle in blast cabinet and dust col- lector in canister. Figure 19. Dust collector installation. -20- Model G0714 (Mfd. Since 05/22)
ON and media blast- ing begins, seal may be broken, causing leakage. 29. Inspect all seals, hose clamps, glove clamps, and window seals for loose fittings, cracks or leaks. Correct as required. -21- Model G0714 (Mfd. Since 05/22)
Page 24
— Investigate and correct strange or unusu- al noises or vibrations before operat- ing machine further. Always disconnect machine from power when investigating or correcting potential problems. Toggle DUST COLLECTOR switch to OFF position. -22- Model G0714 (Mfd. Since 05/22)
Read books/magazines or get formal training before beginning any proj- ects. Regardless of the content in this sec- tion, Grizzly Industrial will not be held liable for accidents caused by lack of training. -23- Model G0714 (Mfd. Since 05/22)
Figure 25. Blast tip installation. door is latched shut. Otherwise gloves and door seal can be pinched and damaged. Use canister plunger to tap filter clean and make sure canister is empty. -24- Model G0714 (Mfd. Since 05/22)
⁄ " in diameter of canister. from original size. 14. When blasting operation complete, disconnect cabinet from power and air supply. -25- Model G0714 (Mfd. Since 05/22)
Air pressure will be diverted higher pressure. Below is a list of Grizzly media back through the suction circuit in the gun and that works well in our blast cabinets.
Page 29
Steel shot does not create most materials. high amounts of dust and it has a superior recycle rate. -27- Model G0714 (Mfd. Since 05/22)
Page 30
When used with the Model G0714, the filter cleaning interval will have to be increased —Garnet (6.5–7.5): Garnet is very effec- to maintain flow.
26”L x 19 ⁄ ”W x 15”H. To reduce this risk, only install accessories recommended for this machine by Grizzly. NOTICE Refer to our website or latest catalog for additional recommended accessories. G0957—80-Gallon 5 HP Extreme-Series...
Inspect suction lines carefully for spots that Figure 32. Dust collector service. collapse or leak during operation. • Inspect work gloves for holes or wear. • Repaint bare metal portions of cabinet (with windows covered). -30- Model G0714 (Mfd. Since 05/22)
1. LED light(s) at fault. 1. Replace LED light(s). dim or will not 2. ON/OFF switch at fault. 2. Test and replace open switch. illuminate. 3. Wiring at fault. 3. Repair for open or shorted wiring connections. -31- Model G0714 (Mfd. Since 05/22)
Place new filter over retaining stud, then re- install wing nut and dust collector. Unlatch dust collector, lift entire motor and filter unit out of canister (see Figure 33), then place it on workbench upside down. -32- Model G0714 (Mfd. Since 05/22)
(see Figure 34). Retainer Motor Cover Screw Motor Cover Screw Latch Canister Brush Housing Figure 36. Retainer removal. Figure 34. Dust collector components. Remove motor cover shown in Figure 34. It is attached with (4) screws. -33- Model G0714 (Mfd. Since 05/22)
Page 36
Re-assemble housings with brass sleeves and new carbon brushes. Inspect commutator surface for carbon track- ing (see Figure 39). Figure 40. Brush power lead location. Carbon Tracking Figure 39. Carbon tracking on commutator surface. -34- Model G0714 (Mfd. Since 05/22)
Page 37
16. Install motor cover and insert dust collector assembly into canister, then latch dust collec- tor in place. 17. Test dust collector operation as outlined in Test Run on Page 21. Correct Incorrect Figure 42. Safe power wire routing. -35- Model G0714 (Mfd. Since 05/22)
Lift LED cover, as shown in Figure 46, and carefully pull it toward you so cover slides out from under (4) screws. Make sure not to break sheet of glass that is resting on rubber cabinet seal under LED cover. -36- Model G0714 (Mfd. Since 05/22)
Page 39
Figure 48. Cords attached to LEDs. 11. Install new LED and connect to cord(s) dis- connected in Step 10. -37- Model G0714 (Mfd. Since 05/22)
Technical Support at (570) 546-9663. The photos and diagrams included in this section are best viewed in color. You can view these pages in color at www.grizzly.com. -38- Model G0714 (Mfd. Since 05/22)
(viewed from behind) 110 VAC 5-15 Plug (As Recommended) DUST COLLECTOR POWER RECEPTACLE Neutral (viewed from behind) Slow-Blow Ground DUST COLLECTOR Fuse 15A POWER CORD w/PLUG Main Power Cord READ ELECTRICAL SAFETY -39- Model G0714 (Mfd. Since 05/22) ON PAGE 38!
SECTION 9: PARTS We do our best to stock replacement parts when possible, but we cannot guarantee that all parts shown are available for purchase. Call (800) 523-4777 or visit www.grizzly.com/parts to check for availability. Blast Cabinet 10V2 11V2-2 11V2-5...
Page 44
LIGHT CORD 16AWG 3C 5' P0714050 FUSE 15A 20 X 80MM P0714022 WIRE CLIP P0714051 BLAST NOZZLE 7MM ID P0714023 ELECTRICAL RECEPTACLE 5-15 -42- BUY PARTS ONLINE AT GRIZZLY.COM! Model G0714 (Mfd. Since 05/22) Scan QR code to visit our Parts Store.
117 P0714117 AIR REGULATOR ASSEMBLY 0-125MPA 102-1 P0714102-1 RUBBER PROTECTOR 118 P0714118 PHLP HD SCR M6-1 X 16 P0714103 HOPPER SEAL BUY PARTS ONLINE AT GRIZZLY.COM! -43- Model G0714 (Mfd. Since 05/22) Scan QR code to visit our Parts Store.
Safety labels help reduce the risk of serious injury caused by machine hazards. If any label comes off or becomes unreadable, the owner of this machine MUST replace it in the original location before resuming operations. For replacements, contact (800) 523-4777 or www.grizzly.com. -44- BUY PARTS ONLINE AT GRIZZLY.COM!
WARRANTY & RETURNS Grizzly Industrial, Inc. warrants every product it sells for a period of 1 year to the original purchaser from the date of purchase. This warranty does not apply to defects due directly or indirectly to misuse, abuse, negligence, accidents, repairs or alterations or lack of maintenance.