1.
General Cleaning Instructions (Refer to Table 401)
WARNING: USE SOLVENT IN A WELL-VENTILATED AREA. AVOID BREATHING FUMES.
AVOID SKIN CONTACT. DO NOT IMMERSE ELECTRONIC PARTS IN
SOLVENT.
The external surfaces of the components of the RESCU 406AFN Emergency Locator Transmitter may
be cleaned with a non-conductive stiff bristle brush or a clean cloth. If use of a solvent is necessary,
apply with a gentle manual agitation and wipe with a lint-free cloth. Afterwards, dry off thoroughly with
compressed air.
Isopropyl Alcohol
Genesolv 2004*
* Although Genesolv 2004 is more astringent than isopropyl alcohol (and may therefore be more
effective in stubborn grease-based situations), it is not miscible with water. Therefore a final
cleaning with isopropyl alcohol may be desirable – particularly where moisture contamination is
present.
© Honeywell International Inc. Do not copy without express permission of Honeywell.
COMPONENT MAINTENANCE MANUAL
1152682
CLEANING
TABLE 401. CLEANING MATERIALS AND COMPOUNDS
(Equivalent substitutes may be used)
Type
Application
General cleaning – a comparatively mild, but water-
miscible solvent.
General cleaning where a solvent more astringent
than isopropyl alcohol is required.
23-24-02
Page 401/402
Oct 27/06