Honeywell RESCU 406AFN Component Maintenance Manual With Illustrated Parts List page 47

Emergency locator transmitter
Table of Contents

Advertisement

3.
Connector Pin-Outs for RESCU 406AFN
Connector pin-outs are given in Tables 102 to 105.
TABLE 102. TRANSMITTER UNIT P/N 1152862-2 CONNECTOR J1 PIN-OUTS
Pin
Pin Label
1
NC
2
NC
3
NC
4
NC
5
NC
6
NC
7
NC
8
ELTON1
9
RFTEST
10
NC
11
DC RETURN
12
ELTON2
13
LEDDRIVE
14
JAA G SWITCH
15
FAA G SWITCH
16
G SW SENSE
© Honeywell International Inc. Do not copy without express permission of Honeywell.
COMPONENT MAINTENANCE MANUAL
1152682
2
Activate the ELT by using a quick throwing motion in the direction of the
arrow, followed by a quick motion in the reverse direction. Verify the unit has
activated by observing that the LED on the control panel is blinking (signifying
activation).
3
After verifying operation, set the switch on the control panel of the transmitter
unit to "OFF".
(I/O)
Input
Used to put transmitter unit into TEST
mode.
Output
Contact closure to ground during
TRANSMIT mode. If not, open circuit.
Input
Used for factory testing only. This
input must be open circuit during
usual operation.
Output
DC ground supplied by the chassis of
the transmitter unit.
Output
Contact closure to ground during
TRANSMIT mode. At other times,
open circuit.
Output
Pulsed output to drive LED.
Input
Contact closure to G SW SENSE to
make selection of JAA G-Switch.
Input
Contact closure to G SW SENSE to
make selection of FAA G-Switch.
Output
Has function as contact closure for
JAA G SWITCH or FAA G SWITCH.
Description
23-24-02
Requirements
Optional
Optional
Optional
Required
Optional
Optional
Required if
aircraft is
operated under
JAA regulations.
Required if
aircraft is
operated under
FAA regulations.
Required
Page 114
Oct 27/06

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1152682-2

Table of Contents