Installing The Tap Housing In A Pedestal; To Install The Tap Housing In A Pedestal - Cisco Surge-Gap Multimedia Tap Installation And Operation Manual

Table of Contents

Advertisement

Installing the Tap Housing in a Pedestal

The pedestal-mounted configuration has the feeder cable entering and exiting the
unit from the bottom. The tap without traps or filters fits in a 6-in. round or square
pedestal. A larger pedestal is needed if traps or filters are installed.

To Install the Tap Housing in a Pedestal

Follow these steps to install a tap housing in a pedestal.
1
Begin this procedure with the faceplate removed. Refer to To Remove the
Faceplate (on page 20).
2
Using a 3/8-in. wrench, remove the strand bolt and strand clamp from the
housing.
3
Mount the housing to the pedestal-mounting bracket using the strand bolt. Use
the strand clamp as a spacer, if necessary.
4
Using a 3/8-in. wrench, tighten the strand bolt from 30 in-lb to 40 in-lb (3.4 Nm
to 4.5 Nm).
4013399 Rev C