How to Set User Defined Busy Tone Setting
- Help
IVD/voip/tone/user_defined> busy ?
- Display the setting
IVD/voip/tone/user_defined> busy -s
- Edit frequency and cadence for busy tone
IVD/voip/tone/user_defined> busy <Lowfreq> <Highfreq> <Ton1> <Toff1> <Ton2>
<Toff2>
Lowfreq
Highfreq
Ton1(msec)
TOff1(msec)
Ton2(msec)
Toff2(msec)
How to Set User Defined Ringing Tone Setting
- Help
IVD/voip/tone/user_defined> ringing ?
- Display the setting
IVD/voip/tone/user_defined> ringing -s
- Edit frequency and cadence for ringing tone
IVD/voip/tone/user_defined> ringing <Lowfreq> <Highfreq> <Ton1> <Toff1> <Ton2>
<Toff2>
Lowfreq
Highfreq
Ton1(msec)
TOff1(msec)
Ton2(msec)
Toff2(msec)
28
Assign a low frequency number in Hertz unit.
(unit is HZ) (Default is 350)
Assign a high frequency number in Hertz unit.
(unit is HZ) (Default is 440)
The duration of the first ringing.
(10msec per unit) (Default is 0)
The silence duration after the first ringing.
(10msec per unit) (Default is 0)
The duration of the next continuous ringing.
(10msec per unit) (Default is 0)
The silence duration after the next continuous ringing.
(10msec per unit) (Default is 0)
Assign a low frequency number in Hertz unit.
(unit is HZ) (Default is 440)
Assign a high frequency number in Hertz unit.
(unit is HZ) (Default is 480)
(10msec per unit) (Default is 0)
(10msec per unit) (Default is 0)
(10msec per unit) (Default is 200)
(10msec per unit) (Default is 400)
Quick Start Guide for VigorAccess IVD