Technical Data; Certifications - Honeywell 013080 Operating Instructions Manual

Mb touchscreen controlpanel
Hide thumbs Also See for 013080:
Table of Contents

Advertisement

Operating Instructions MB TouchScreen ControlPanel

13. Technical data

Rated operating voltage U_b
Operating voltage range
Max. permissible ripple
Current consumption stand by mode
at 12V DC
at 10V DC
Current consumption at 12V DC
by max. screen brightness:
Current consumption at 10V DC
by max. screen brightness:
Integrated reader
Reading distance
Frequency range, transmission power:
proX1, proX2
mifare
Screen diagonal (visible)
Screen format
Environmental class as per VdS
Environmental class as per EN 50131-3
Protection class as per EN 60529
Operating temperature range
Storage temperature range
Relative humidity
Weight
Dimensions (W x H x D)
Colour
*1) Specified reading distance on non-metallic mounting surface.
On metallic surfaces, the reading distance may be be reduced slightly.
The specified reading distance can only be garanteed by using data carriers provided by our
company.
When using the encryption method mifare DESFire EV1/EV2, the reading distance may be lower
for EV1 data carriers.
Hereby, the Novar GmbH declares that the radio equipment MB TouchScreen PanelControl,
Item no. 013080 and 013081 is in compliance with Directive 2014/53/EU.
T h e f u l l t e x t o f t h e E U d e c l a r a t i o n c a n b e d o w n l o a d e d f r o m o u r h o m e p a g e
https://www.security.honeywell.de/ Service / Download.

14. Certifications

VdS approval no.
EN Conformity
SES Conformity
Type B
12V DC
9V DC bis 15V DC
1Vpp (peak-to-peak)
190mA
220mA
- average 230mA
- average 270mA
IK2/proX1, IK3/proX2 and mifare DESFire EV1, EV2
0 ~ 3cm for proX and mifare data carrier (*1)
125 kHz <10dBµA/m in 10m distance
13,56 MHz, <0dBµA/m in 10m distance
9" (22,8cm)
16 : 9
II
Class II
IP30
-5 °C to +45 °C
-25 °C to +60 °C
93% non-condensing
850 g
218 x 162 x 30 mm
white (similar to RAL 9016), black (similar to RAL 9017)
G121014
VdS2252 Class C / Environmental class II
EN 50131-3: Grade 3
EN 50131-1: Environmental class II
SES-EMA-RL-T2:2021-04
When used in systems according to VdS, EN or SES in the
monitored area, for internal use only.
- max. 390mA
- max. 480mA
17