SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
Table 4-3 Cable Shielding and Termination Specifications
Cable
RF TX and RX
When installing the Aspire-200, follow the cabling requirements listed below:
The maximum recommended length for USB data connections is 16 feet.
The maximum recommended length for USB power connections is 30 feet.
Ethernet LAN/WAN and ISDN cables must meet flammability and TIA/EIA568-A CAT 5E requirements.
USB cables must meet flammability requirements.
Twisted shielded pairs must meet ARINC 741 wiring requirements or equivalent.
Wire size recommendations for the HDU:
Wire size recommendations for the CCU:
Wire size recommendations for the IPLD:
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Aspire-200
Conductor Type
Coaxial
For +28 VDC HOT (BP2), +28 VDC RTN GND (BP3), and Chassis GND (BP8),
use 16 AWG
Unless otherwise specified, for signaling, use 22 AWG.
For +28VDC (J1-A), +28 VDC RTN (J1-B), and Chassis GND (J1-C), use 20
AWG
Unless otherwise specified, for discrete signaling, use 22 AWG.
Unless otherwise specified, for twisted shielded pairs, use 22 AWG conductors.
For +28 VDC (J4-Z), +28 VDC RTN GND (J4-W), use 16 AWG
Unless otherwise specified, for signaling, use 22 AWG.
Single
Multiple
Point
Point
Yes
95%
23-15-45
Minimum
Conductor
Coverage by
Shield
Page 4-18