Download Print this page

Honeywell ASPIRE-200 User, Installation, And Maintenance Manual page 115

Advertisement

SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
INMARSAT TYPE APPROVAL: ------
CHAN #1: ABCDEF
(AERO WITH MPDS)
B. Checking the APN
DATA I/O APN ?[bgan.inmarsat.com = ?
2. Checking System Reports
The Aspire-200 MPU provides diagnostic reports that display information about various system functions.
A. Viewing System Reports
Enter 1 thru 153 to toggle report on/off
X
turn off all reports
ESC
return to PREVIOUS MENU
1 OFF OFF messages to card #1
2 OFF OFF hex output to card #1
3 OFF OFF responses from card #1
4 OFF OFF hex input from card #1
5 OFF OFF card #1 misc info
6 OFF low-level ort transfer to IPLD
7 OFF IPLD cable cal
8 OFF low-level call log tx to IPLD
9 OFF channel card call status
10 OFF channel card THA codes
11 OFF channel card errors
12 OFF IRS input
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Aspire-200
The Aspire-200 MPU can display EEPROM parameters, including the APN.
To view the strapped APN:
1. Connect to the HDU maintenance port—see "Connecting to the Aspire-200
Maintenance Port" on page 1..
2. In the maintenance menus, press CTRL + N to navigate to menu 3.
3. To view Miscellaneous EEPROM parameters, press m.
The list of parameters appears.
To view a report:
1. Connect to the HDU maintenance port—see "Connecting to the Aspire-200
Maintenance Port" on page 1..
2. To view a list of available reports, press =.
The list of available reports appears.
<CTRL> N
show next page
18 OFF port antenna arinc input
19 OFF port antenna maintenance word
20 OFF port antenna status word
21 OFF call codes
22 OFF spot beam selection
23 OFF standard output
24 OFF doppler, antenna az/el
27 OFF IPLD/channel card backoffs
28 OFF miscellaneous digital inputs
29 OFF channel card A_AM msgs
30 OFF multi-control arinc bus
31 OFF ocean region info