SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
6. Type the number next to the available NAV type.
7. To configure the NAV2 type, press the number next to the NAV2 Type
parameter, and then press ENTER.
The NAV2 Type prompt appears.
NAV2 TYPE
NOT INSTALLED
4=HYBRID
7=AHRS
8=FMS
8. Type the number next to the available NAV2 type.
9. To configure the NAV3 type, press the number next to the NAV3 Type
parameter, and then press ENTER.
The NAV3 Type prompt appears.
NAV3 TYPE
NOT INSTALLED
4=HYBRID
7=AHRS
8=FMS
10. Type the number next to the available NAV3 type.
11. If you have finished configuring the HDU, restart the HDU.
To configure the NAV transmission speed:
1. In the maintenance menus, to navigate to menu 3, press CTRL + N.
2. In menu 3, to access miscellaneous EEPROM parameters, press m.
The list of miscellaneous EEPROM parameters appears.
3. To navigate the list of parameters, press CTRL + N.
4. Type the number next to Primary Nav Receive Speed, and then press ENTER.
5. To set the interface to high speed, press 1, and to set the interface to low-speed,
press 0.
6. Type the number next to Secondary Nav Receive Speed, and then press
ENTER.
7. To set the interface to high speed, press 1, and to set the interface to low-speed,
press 0.
8. Type the number next to Tertiary Nav Receive Speed, and then press ENTER.
9. To set the interface to high speed, press 1, and to set the interface to low-speed,
press 0.
10. Restart the HDU.
You can restart the HDU using menu 2, option Z.
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Aspire-200
0="NOT INSTALLED" 1=INERTIAL
= ?
0="NOT INSTALLED" 1=INERTIAL
= ?
23-15-45
3=GNSS
3=GNSS
Page 5-6
28 Feb 2018

Advertisement