Cisco 6100 Installation Procedures Manual page 35

Thermal upgrade kit

Advertisement

Figure 19
Cisco
6100
Fan tray
See Figure 20 for a close view of the alarm contact pinouts. For pinout descriptions, see the Cisco 6100
with NI-1 Direct Connect Installation Guide.
Figure 20
Pin 7
Pin 8
Use a wire stripper to remove the casing from both ends of the wires.
Step 2
Wire P2 on the backplane of the fan tray to P14 (pin 7) on the backplane of the Cisco 6100 to connect
Step 3
the Fan Alarm+ contact. Use a wire wrapping tool to attach the wire to the contacts.
Wire P2 on the backplane of the fan tray to P15 (pin 8) on the backplane of the Cisco 6100 to connect
Step 4
the Fan Alarm– contact. Use a wire wrapping tool to attach the wire to the contacts.
78-10158-01
Wiring the Fan Tray Alarm Contacts
P14
P15
+