Honeywell Midas-M User Manual page 91

Hide thumbs Also See for Midas-M:
Table of Contents

Advertisement

ModBus
Information R/W
Register
Number
40031
Flow rate in
cc/minute
40032 ~
Reserved for
40037
future
expansion
Channel 1 Information
40038
Gas Selection R
40039 to
Alarm1
40040
threshold
40041 to
Alarm2
40042
threshold
40043
Measuring
units
40044
Alarm Status
40045
Fault Status
Midas-M
Data
Data
Size
Type
(Byte)
R
u16
2
R
u16
12
u16
2
R/W
f32
4
R/W
f32
4
R
u16
2
R
u16
2
R
u16
2
Description
Current pump
flow
bit 0 - 7 : Gas ID bit 8 - 15 : Cell ID
Concentration
0 : N/A 1 : mA 2 : %LEL 3 : % volume 4
units
: ppb 5 : ppm 6 : mg/m3 7 ~ 15:
reserved
bit 0 : Alarm 1 active bit 1 : Alarm 2
active
This is the bit
bit 0 : Baseline Warning (m10) bit 1 :
order
Overrange Warning (m11) bit 2 :
representation
Calibration Expire Soon (m20) bit 3 :
of the channel
Cell Expire Soon (m21) bit 4 :
fault status. If
Temperature Warning (m40) bit 5 :
any fault exists
Baseline Fault (F10) bit 6 : Calibration
this will take a
Expired (F20) bit 7 : Cell Expired
value in each
(F21) bit 8 : Temperature Exceeded
bit.
(F40) bit 9 : Cell Failure Refelex (F50)
bit 10 : Cell Failure IR Comm. (F51) bit
11 : Cell EEPROM Read Error (F52)
bit 12 : Cell EEPROM Corrupted
(F53) bit 13 : Cell Failure IR Volt.
(F54) bit 14~15 : : for future expansion
91
Note
User Manual