Install the Cisco ONS 15310-MA SDH
During this procedure, wear grounding wrist straps to avoid electrostatic discharge (ESD) damage to
Warning
the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock
yourself. Statement 94
Invisible laser radiation could be emitted from the end of the unterminated fiber cable or connector.
Warning
Do not stare into the beam directly with optical instruments. Viewing the laser output with certain
optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100
mm could pose an eye hazard. Statement 1056
Class I (CDRH) and Class 1M (IEC) laser products. Statement 1055
Warning
Warning
Use of controls, adjustments, or performing procedures other than those specified may result in
hazardous radiation exposure. Statement 1057
Warning
The Ethernet ports and the LAN port on 15310E-CTX-K9 cards of ONS15310-MA SDH are intra-building
ports and are suitable only for connecting to cat-5 shielded (STP) cabling grounded at both ends.
Statement 1084
The CRAFT ports of ONS15310-MA SDH are intra-building ports used only for setup and maintenance
Warning
purposes by trained personnel and are not connected during normal operation. Statement 1085
Caution
Do not install a 15310E-CTX-K9 card in an ONS 15310-MA SDH if the ambient temperature exceeds
149 degrees F (65 degrees C).
Always use the supplied ESD wristband when working with a powered ONS 15310-MA SDH. Plug the
Caution
wristband cable into either of the ESD jacks, on the far left and right faceplates in the shelf.
If protective clips are installed on the backplane connectors of the cards, remove the clips before
Note
installing the cards.
Install a 15310E-CTX-K9 card in Slot 3 or 4
Step 1
Open the card ejector.
a.
Use the ejector at the top of the card and firmly slide the card along the guide rails until the card
b.
plugs into the receptacle at the back of the slot.
Verify that the card is inserted correctly and close the ejector on the card.
c.
78-18668-01
(Figure
1-8):
Cisco ONS 15310-MA SDH Procedure Guide, R9.0