Level lll Cycle Programming – C Values
Several Level III program parameters can be adjusted to
fine-tune a conditioners operation for non-standard
applications. Typically these parameters will not need to
be adjusted as the default settings accommodate most
applications. Contact your Water Treatment Professional
before attempting any programming. The parameters are
C#
Description
C1
Backwash
C2
Regenerant Draw
C3
Slow Rinse
C5
Fast Rinse
C8
Regenerant Refill
a. Only adjustable when the 293 filter valve has been selected.
Minimum
Range
Increments
0 – 200
1 Min
a
0 – 200
1 Min
0 – 200
1 Min
0 – 200
1 Min
a
0 – 200
1 Min
accessible by pressing and holding the UP and SET buttons
until the display shows a "C" value.
Note: The control must by in the treated water position
to change settings.
Default
Setting
Flow rate dictated by size of drain line flow
14
controller
Automatically calculated from resin volume
See Notes
and salt dosage settings
Automatically calculated from resin volume
See Notes
and salt dosage settings
6
Rinses residual regenerant from tank
Automatically calculated from resin volume
See Notes
and salt dosage settings
35
Notes