GE Logix 764 Operation Manual page 33

With 293 magnum it; 298 magnum it twin alternating; twin parallel; single with remote regeneration start; multi-single tank with lockout
Table of Contents

Advertisement

8. If the water level is receding from the regenerant tank
you can quick cycle the control to the C8 Regenerant
tank refill position.
A. The control will cycle to the regenerant tank
refill cycle, and water will be directed down
through the regenerant line to the regenerant
tank. Let the water flow through the line until
all air bubbles have been purged from the
line. Note: Do not let the water flow down the
line to the tank for more than one to two
minutes, or the tank may overfill.
9. Repeat steps 4 and 8 for each additional tank.
10. Finally, turn on a faucet plumbed after the water
conditioner. Run the faucet until the water runs clear.
11. Add the appropriate amount of regenerant to
regenerant tank.
The Water Conditioning System is Now
Fully Operational
Note: After any control reset (valve type or system
change, etc.) it is necessary to initiate a manual
regeneration and quick cycle through it. This will ensure
the control and cam are synchronized. If not synchronized
will display and the control will drive cams to the
err#
correct position for valve and system type programmed..
31