Level IV Viewing History - H Values

Historical information can be viewed by pressing the SET
and DOWN buttons simultaneously, with the 764 control in
the home position. Release both buttons when the control
displays an "H" value. Press the UP or DOWN buttons to
navigate to each setting.
Table 4 History Data
H#
a
H0
Initial Setting Value
H1
Days since last regeneration
H2
Current Flow Rate
H3
Water used today in gallons or/m
H4
Water used since last regeneration in gallons or/m
a
H5
Total water used since reset in 100s
a
H6
Total water used since reset in 1,000,000
H7
Average usage for Sunday in gallons or m
H8
Average usage for Monday in gallons or m
H9
Average usage for Tuesday in gallons or m
H10 Average usage for Wednesday in gallons or m
H11 Average usage for Thursday in gallons or m
H12 Average usage for Friday in gallons or m
H13 Average usage for Saturday in gallons or m
H14 Average service cycle
a
H15
Peak Flow Rate
H16 Day and Time of Peak Flow Rate
a
H17
Months since service
H18 Water used since last regeneration - Tank 1
H19 Water used since last regeneration - Tank 2
a. H0, H5, H6, H15, H17 values can be reset by pressing and holding
displayed.

Program Reset

The 764 control can be reset to original factory
parameters when viewing the H0 parameter. Press and
hold the SET button for three seconds while H0 is
displayed. Release the button. All settings except for Time
of Day and Day of Week will be reset. The 764 Logix control
will now display the valve and system type. Refer to Level
I Programming.
Description
3
since Time of Regeneration 0-131,070 or 0-1,310.70 m
3
3
3
3
3
3
3
3
36
Range
Cubic Feet or Liters
0 - 255
Depends on turbine used
0-131,070 or 0-1,310.70 m
0-999900 gallons or
3
0-9999 m
6
4,294 x 10
gal or
4
3
4264 x 10
m
0-131,070 gallons
3
or 0-1,310.70 m
0-131,070 gallons
3
or 0-1,310.70 m
0-131,070 gallons
3
or 0-1,310.70 m
0-131,070 gallons
3
or 0-1,310.70 m
0-131,070 gallons
3
or 0-1,310.70 m
0-131,070 gallons
3
or 0-1,310.70 m
0-131,070 gallons
3
or 0-1,310.70 m
0-255 days
0-200 gpm or 1000 Lpm
Time and day that peak flow
occurred
0-2184 months
0-131,070 gallons
3
or 0-1,310.70 m
0-131,070 gallons
3
or 0-1,310.70 m
for 3 seconds while the value is being
Note: After any control reset (valve type or system
change, etc.) it is necessary to initiate a manual
regeneration and quick cycle through it. This will ensure
the control and cam are synchronized. If not synchronized
err#
will display and the control will drive cams to the
correct position for valve and system type programmed.