Table 12 Iva-81D Ta/Vsi Leading Particulars - Honeywell CAS-100 Maintenance Manual

Collision avoidance system
Table of Contents

Advertisement

Characteristic
Form Factor
Components
Maximum Weight
Overall Dimensions
Mounting
Software Certification
Power Requirements
Primary
Lighting
Reference
Operating Temperature Range
Number of Intruder Aircraft Displayed
Display
Vertical Speed Input
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
MAINTENANCE MANUAL
CAS-100 COLLISION AVOIDANCE SYSTEM
Table 12. IVA-81D TA/VSI Leading Particulars
3ATI x 7.5 inches deep
Solid state, no mechanical parts
3.0 lb (1.4 kg)
See Outline Drawing, Figure 2013.
Front, panel mount; Marmon clamp or equivalent
D0-178B, Level B
115 V, 400 Hz or 28 V dc primary power. Maximum power
dissipation of 40 Watts (short term at cold temperature), at
full brightness including display warm-up at low temperature.
5 V ac or dc, or 28 V dc
±12 V dc if altitude rate source input is ARINC 575 analog
26 V ac if altitude rate source is ARINC 565 analog
-20C to +70C
Maximum number determined by TCAS processor program
strap configuration.
High resolution, full color dot matrix LCD. Combination
vertical speed and traffic display.
The IVA-81D meets the requirements of both type B and type
C VSI indicators. Pneumatic or air data electrical input. Both
ARINC 500 and 700 series air data input accepted.
Description
34-45-47
Page 33
1 Dec 2003

Hide quick links: