Table 11 Iva-81B Ra/Vsi Leading Particulars - Honeywell CAS-100 Maintenance Manual

Collision avoidance system
Table of Contents

Advertisement

Characteristic
Form Factor
Components
Maximum Weight
Overall Dimensions
Mounting
Power Requirements
Operating Temperature Range
Display
Vertical Speed Input
Inputs from TCAS
Pneumatic Connector
Electrical Connector
TSO
Environmental Certification
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
MAINTENANCE MANUAL
CAS-100 COLLISION AVOIDANCE SYSTEM
Table 11. IVA-81B RA/VSI Leading Particulars
3ATI x 7.5 inches deep
Electromechanical and solid state
2.9 lb (1.3 kg)
See Outline Drawing, Figure 2012.
Front, panel mount
115 V 400 Hz, 20 watts primary power
±12 V dc reference power if altitude rate source input is
ARINC 575 analog
26 V ac reference power if altitude rate source is ARINC 565
analog
5 V ac or dc lighting power
-15C to +70C
Lamps around the periphery of a fixed vertical speed scale
and electro-mechanical needle. Combination vertical speed
and RA display.
The IVA-81B meets the requirements of both type B and type
C VSI indicators. Pneumatic or air data electrical input.
High-speed ARINC 429
See Outline Drawing, Figure 2012.
See Outline Drawing, Figure 2012.
C119a, C8c
Refer to Table 14.
Description
34-45-47
Page 32
1 Dec 2003