Honeywell CAS-100 Maintenance Manual page 163

Collision avoidance system
Table of Contents

Advertisement

MAINTENANCE MANUAL
CAS-100 COLLISION AVOIDANCE SYSTEM
(5)
Stored Faults
To push the Select button when STORED FAULTS (see main menu Figure 1003) is the
active selectable item, causes the Stored Faults screen to be shown (Figure 1005). The
fault data is shown five legs back from the most recent fault to the oldest fault. The title
of the Stored Fault Display shows in which leg the stored fault is found. The title shows
the current leg minus the number of legs to where the fault is kept. For example, LEG-2
shows the fault is found two legs back from the present leg. If the current leg equals the
leg with the fault, then the title is INBOUND.
The date and time the first fault of the flight leg occurred is shown in the screen title.
PHASE shows the flight phase (1-16) of the faults first occurrence in the flight leg.
OCCUR shows the number of occurrences of the fault in the fault leg.
The Figure 1006 is an example of a stored fault procedure.
Typical First and Last Pages of Stored Faults Display Screen
Figure 1005
Page 1022
34-45-47
1 Dec 2003
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents