Associating The Temperature Alarms To A Relay; Configuring The Fcs Bit Error Rate Alarm; Setting The Fcs Error Threshold; Setting The Fcs Error Hysteresis Threshold - Cisco Catalyst 2950 Software Configuration Manual

Hide thumbs Also See for Catalyst 2950:
Table of Contents

Advertisement

Chapter 3
Configuring Catalyst 2955 Switch Alarms

Associating the Temperature Alarms to a Relay

By default, the primary temperature alarm is associated to the major relay. You can use the alarm facility
temperature command to associate the primary temperature alarm to the minor relay, to an SNMP trap,
to a syslog message, or to associate the secondary temperature alarm to the major or minor relay, an
SNMP trap, or a syslog message.
Beginning in privileged EXEC mode, follow these steps to associate the secondary temperature alarm to
a relay:
Command
Step 1
configure terminal
Step 2
alarm facility temperature
{primary | secondary} relay {major
| minor}
Step 3
alarm facility temperature
{primary | secondary} notifies
Step 4
alarm facility temperature
{primary | secondary} syslog
Step 5
end
Step 6
show alarm settings
Step 7
copy running-config startup-config (Optional) Save your entries in the configuration file.
Note
Before you can use the notifies command to send alarm traps to an SNMP server, you must first set up
the SNMP server by using the snmp-server enable traps alarms global configuration command. See
the
Use the no alarm facility temperature secondary to disable the secondary temperature alarm.
This example sets the secondary temperature alarm to the minor relay, with a lower high temperature
threshold value of 45
and an SNMP server.
Switch(config) # alarm facility temperature secondary 45
Switch(config) # alarm facility temperature secondary relay minor
Switch(config) # alarm facility temperature secondary syslog
Switch(config) # alarm facility temperature secondary notifies
This example sets the first (primary) temperature alarm to the major relay. All alarms and traps
associated with this alarm will be sent to a syslog server.
Switch(config) # alarm facility temperature primary syslog
Switch(config) # alarm facility temperature primary relay major

Configuring the FCS Bit Error Rate Alarm

This section describes how to configure the FCS bit error rate alarm on your switch:
78-11380-12
Purpose
Enter global configuration mode.
Associate the primary or secondary temperature alarm to a relay
Configure sending primary or secondary temperature alarm traps to an
SNMP server.
Configure sending primary or secondary temperature alarm traps to a syslog
server.
Return to privileged EXEC mode.
Verify the configuration.
"Enabling SNMP Traps" section on page
o
C. All alarm and traps associated with this alarm will be sent to a syslog server
Setting the FCS Error Threshold, page 3-8
Setting the FCS Error Hysteresis Threshold, page 3-8
3-11.
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
Configuring Catalyst 2955 Switch Alarms
3-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 2955

Table of Contents