Understanding Backbonefast - Cisco Catalyst 2950 Software Configuration Manual

Hide thumbs Also See for Catalyst 2950:
Table of Contents

Advertisement

Chapter 15
Configuring Optional Spanning-Tree Features
Figure 15-6
GigaStack GBIC Module Connections and Spanning-Tree Convergence
Catalyst 3550-12T
1
1
1
1
1
1
Catalyst 3508G XL
Catalyst 2950G-24
1
2
3
4
5
6
7
8
9
10
11 12
13 14
15 16
17 18
1X
11X
13X
2X
12X
14X
Catalyst 2950G-12
1
2
3
4
5
6
7
8
9
10
11 12
1X
11X
2X
12X

Understanding BackboneFast

BackboneFast detects indirect failures in the core of the backbone. BackboneFast is a complementary
technology to the UplinkFast feature, which responds to failures on links directly connected to access
switches. BackboneFast optimizes the maximum-age timer, which determines the amount of time the
switch stores protocol information received on an interface. When a switch receives an inferior BPDU
from the designated port of another switch, the BPDU is a signal that the other switch might have lost
its path to the root, and BackboneFast tries to find an alternate path to the root.
BackboneFast, which is enabled by using the spanning-tree backbonefast global configuration
command, starts when a root port or blocked port on a switch receives inferior BPDUs from its
designated switch. An inferior BPDU identifies a switch that declares itself as both the root bridge and
the designated switch. When a switch receives an inferior BPDU, it means that a link to which the switch
is not directly connected (an indirect link) has failed (that is, the designated bridge has lost its connection
78-11380-12
GigaStack GBIC connection for fast convergence
Catalyst 3500
1
1
1
1
1
2
Catalyst 3500
XL
1
2
Catalyst 2950
19 20
21 22
23 24
15X
16X
1
2
Catalyst 2950
1
2
GigaStack GBIC connection for normal convergence
Catalyst 2950G-12
1
2
3
4
5
6
7
8
9
10
11 12
1X
11X
2X
12X
Catalyst 2950G-24
1
2
3
4
5
6
7
8
9
10
11 12
13 14
15 16
1X
11X
13X
2X
12X
14X
Catalyst 2950G-48
1
2
3
4
5
6
7
8
9
10
9
10
9
10
9
10
1
2
3
4
5
6
7
8
1X
1X
11X
2X
2X
12X
Catalyst 3550-12T
1
1
1
1
1
Catalyst 2950G-24
1
2
3
4
5
6
7
8
9
10
11 12
13 14
1X
11X
13X
2X
12X
14X
Catalyst 2950G-48
1
2
3
4
5
6
7
8
9
10
9
10
9
10
9
10
1
2
3
4
5
1X
1X
11X
2X
2X
12X
Catalyst 2950
1
2
Catalyst 2950
17 18
19 20
21 22
23 24
15X
16X
1
2
1
2
Catalyst 2950
9
10
9
10
9
10
9
10
1
2
3
4
5
6
7
8
9
10
9
10
9
10
9
10
1X
11X
1
2
2X
12X
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
Understanding Optional Spanning-Tree Features
Catalyst 3500
1
1
1
1
1
1
2
Catalyst 2950
15 16
17 18
19 20
21 22
23 24
15X
16X
1
2
Catalyst 2950
6
7
8
9
10
9
10
9
10
9
10
1
2
3
4
5
6
7
8
9
10
9
10
9
10
9
10
1X
11X
1
2
2X
12X
15-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 2955

Table of Contents