FUNCTION (Operation / inspection mode)
■ INSTALL
COPIER (Service mode for copier) > FUNCTION (Operation / inspection mode) > INSTALL
STRD-POS
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Related Service Mode
CARD
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Related Service Mode
AINR-OFF
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
E-RDS
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Related Service Mode
Supplement/Memo
Scan position auto adj in DADF mode
To adjust the DADF scanning position automatically.
At DADF installation/uninstallation
1) Close the DADF.
2) Select the item, and then press OK key.
The operation automatically stops after the adjustment.
3) Write the value displayed by COPIER> ADJUST> ADJ-XY> STRD-POS in the service label.
Write the adjusted value in the service label.
At normal termination: OK, At abnormal termination: NG
COPIER> ADJUST> ADJ-XY> STRD-POS
Card number setting
To set the card number to be used for Card Reader.
A series of numbers from the entered number to the number of cards specified by CARD-RNG
can be used.
- At installation of the Card Reader
- After replacement of the HDD
1) Enter the number, and then press OK key.
2) Turn OFF/ON the main power switch.
The card management information (department ID and password) is initialized.
1 to 2001
1
COPIER> OPTION> FNC-SW> CARD-RNG
ON/OFF warm-up rotn deact:dor open/close
To set whether to disable the warm-up rotation when opening and closing the door.
By selecting 1, printing can be executed without auto adjustment at warm-up rotation when
analyzing the cause of a problem.
When printing and checking without auto adjustment at warm-up rotation when analyzing the cause
of a problem
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: OFF (warm-up rotation enabled), 1: ON (warm-up rotation disabled)
0
Set use/no use of Embedded-RDS function
To set whether to use the Embedded-RDS function.
When using Embedded-RDS
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and RGW-ADR as a set.
0 to 1
0: Not used, 1: Used (All the counter information is sent.)
It differs according to the location.
COPIER> FUNCTION> INSTALL> RGW-PORT, COM-TEST, COM-LOG, RGW-ADR
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to the sales company's server via SOAP protocol
690
8. Service Mode