Alarm Code; Alarm Code Details - Canon imageRUNNER ADVANCE C255 Series Service Manual

Table of Contents

Advertisement

Alarm Code

Alarm Code Details

00-0085
A. Operation / B. Cause /
C. Remedy
00-0246
A. Operation / B. Cause /
C. Remedy
00-0247
A. Operation / B. Cause /
C. Remedy
01-0001
A. Operation / B. Cause /
C. Remedy
01-0002
A. Operation / B. Cause /
C. Remedy
01-0004
A. Operation / B. Cause /
C. Remedy
01-0005
A. Operation / B. Cause /
C. Remedy
04-0001
A. Operation / B. Cause /
C. Remedy
A notice of stat
-
Error code display (4-digit)
Soft counter PCB cannot write normally.
Error code display (4-digit)
Soft counter PCB cannot restore data.
Notification of disabled to obtain counter values for a certain period of time
Counter information is not set to UGW
* Not displayed on service mode history due to the alarm being generated by UGW
No change in device status after specified period of time has passed (RDS server creates)
-
Notification of IP address change
IP address has been changed
* Not displayed on service mode history due to the alarm being generated by UGW
Restricted operation notification
The device entered limited function mode for some reason.
* Not displayed on service mode history due to the alarm being generated by UGW
Cassette 1 Lifter error
Cause: Error in Lift Motor or Lifter Sensor
Measures:
1. While Cassette 1 is removed, turn ON the power and then insert Cassette 1.
When there is operation sound of the motor
1-1. Check the harness/connector between the DC Controller and the Cassette 1 Lifter Sensor
2-1. Check if the Cassette 1 Lifter Sensor is installed.
3-1. Extend the Sensor Flag of the Cassette 1 Lifter Sensor by approx. 1.5 mm with Plastic Film,
etc.
4-1. Check the condition of the gear at the host machine side (to see if there is missing or swing
with the gear)
5-1. Replace the Cassette 1 Lifter Sensor
6-1. Replace the DC Controller PCB
When there is no operation sound of the motor
1-2. Check the harness/connector between the DC Controller and the Cassette 1 Lifter Motor
2-2. Check conduction of the fuse of the DC Controller
3-2. Check the condition of the gear at the host machine side (to see if there is something missing
or swing with the gear)
4-2. Check the Cassette 1 Lifter Motor
5-2. Replace the DC Controller