SPECIFICATIONS

Communications

Testing & Certification
1–28
ETHERNET – BASE OFFERING
Modes: ..................................................................... 10/100 Mbps
One Port:................................................................. RJ45
Protocol:.................................................................. Modbus TCP
ETHERNET – CARD OPTION "C" - 2X COPPER (RJ45) PORTS
Modes: ..................................................................... 10/100 MB
Two Ports:............................................................... RJ45 (with this option both enabled ports are on the
Protocols:................................................................ Modbus TCP, DNP3.0, IEC60870-5-104, IEC 61850, IEC 61850
ETHERNET – CARD OPTION "S" - 2X ST FIBER PORTS
Modes: ..................................................................... 100 MB
Two Ports:............................................................... ST (with this option both enabled ports are on the
Protocols:................................................................ Modbus TCP, DNP3.0, IEC60870-5-104, IEC 61850, IEC 61850
Wavelength:.......................................................... 1310nm
Typical link distance:......................................... 4 km
USB
Standard specification:.................................... Compliant with USB 2.0
Protocols:................................................................ Modbus TCP, TFTP
SERIAL
RS485 port: ............................................................ Isolated
Baud rates: ............................................................ Supports 9600, 19200, 38400, 57600, and 115200 kbps
Response time: .................................................... 10 ms typical
Parity: ....................................................................... None, Odd, Even
Protocol:.................................................................. Modbus RTU, DNP 3.0, IEC 60870-5-103
Maximum distance:........................................... 1200 m (4000 feet)
Isolation: ................................................................. 2 kV
WIFI
Standard specification:.................................... IEEE802.11bgn
Range:...................................................................... 30 ft (direct line of sight)
REMOTE MODBUS DEVICE PROFILE
Device Name: ....................................................... BSG3 (13 alphanumeric characters maximum)
IP Address: ............................................................. 0.0.0.0 – standard Ethernet address
Slave Address: ...................................................... 254 (1 to 254)
Modbus Port:......................................................... 502 (0 to 10000, default 502)
Poll Rate: ................................................................. 3 minute (OFF, 3 to 120 minutes), the continuous mode poll
Trigger:..................................................................... Off (any FlexLogic Operand), the trigger mode is based on
APPROVALS
Applicable Council Directive
communications card; the Ethernet port located on the base
CPU is disabled)
GOOSE, IEEE 1588, SNTP, IEC 62439-3 clause 4 (PRP)
communications card; the Ethernet port located on the base
CPU is disabled)
GOOSE, IEEE 1588, SNTP, IEC 62439-3 clause 4 (PRP)
interval is defined as the poll rate interval
the FlexLogic operand designed to trigger the poll
According to
869 MOTOR PROTECTION SYSTEM – INSTRUCTION MANUAL