4.3 AE CONTROL ( MENU => CAMERA => AE CONTROL)
Depending on your dome camera, you will see either the following screen or the next.
MODE
SLOW SHUTTER : x10
IRIS
GAIN
BRIGHT
SHUTTER
MAX GAIN
DNR
EXIT MENU
MODE
SLOW SHUTTER
IRIS
GAIN
BRIGHT
SHUTTER
MAX GAIN
DNR
NOTE : Values in ( ) are for PAL Camera.
AE SETUP
: FULL AUTO
: Auto
: Auto
: 008
: Normal
: 30DB
: OFF
: FULL AUTO / SHUTTER FIX / IRIS FIX / AGC FIX / MANUAL
: OFF / X1~X18 / X20 / X40 / X80 / X160 / X320 / X512
: CLOSE / F16/ F11 / F8.0 / F7.6 / F5.6 / F4.2 / F4.0 / F2.8 / F2.0 /
F1.8 / OPEN
: OFF / 8 DB / 10 DB / ...... / 36 DB / AUTO
: 000 ~ 015 / NORMAL (008: Default)
: 1/60(1/50), 1/100(1/120),1/250, 1/500, 1/1000, 1/2000, 1/4000,
1/10000, 1/20000, 1/50000. 1/100000
: OFF / 8DB / 10DB / ... / 36DB
: OFF / LOW / HIGH