Honeywell EXPTZ-252A Installation&Operation Manual Book page 20

Exptz camera explosive proof security camera
Table of Contents

Advertisement

Honeywell
HWLKS-C-M-1918
Program and Operation
2. ALARM ( MENU => ALARM)
Locate the cursor on ALARM item in the main menu and push the joystick to the right for
ALARM programming of the camera.
NO
: Alarm input number
FUNC
: Priority 1~4 calls Preset(xxx),
Priority 0 supports dedicated functions like a Preset.
PRI
: Lower No. has higher priority, Equal priority alarms will be serviced repeatedly.
IN
: NO/NC - normally open /Closed, OFF - ignore
OUT
: RO1 - Relay out 1
HLD
: Alarm will be held for programmed time (01 to 255 seconds)
LATCH : ON - Shows all alarms including past alarm, OFF - Shows activated alarms only.
There are 4 levels of priority. 0 : Highest priority supports repeated/dedicated functions like a Preset.
1~4: Same level of alarm calls presets one after the other.
Ex) Alarm 01 calls Preset 01, After alarm 01 is released alarm 02, 03 will call preset 48 and preset 01
MAIN MENU
FUNCTION
ALARM
SCREEN
CAMERA
SETUP
PASSWORD
COMMUNICATION
EXIT MENU
ALARM SETUP
NO FUN
PRI
IN
01 001
0
OFF OFF 001
02 002
4
OFF OFF 001
03 003
4
OFF OFF 001
04 004
3
OFF OFF 001
SAVE AND EXIT
OFF - No output.
- 20 -
OUT HLD LATCH
OFF
OFF
OFF
OFF