Inter-Processor Failures; Input Buffer Test Failures - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

SmartPAC 2 with WPC Integration

Inter-processor failures

Problem:
These errors indicate failures that may occur within the main processor or
in the case of status code #38 and #39, in the second processor. The errors
are as follows:
F31
No reply received from second processor to check start request
F33
Incorrect reply received from second processor to mode change message
F34
No reply received from second processor to mode change message
F35
Incorrect reply received from second processor to power-up message
F36
No reply received from second processor to reset error message
F37
No reply received from second processor to compare input buffers
message
H38
The second processor did not receive the power up information correctly
H39
The second processor did not receive the mode information correctly
Remedy:
Try to reset. If errors persist, contact Wintriss Tech Support for
assistance.

Input buffer test failures

Problem:
These errors indicate failures that may occur when WPC performs input
buffer tests within the main processor. The errors are as follows:
F41
Input buffer 1 check incorrect
F42
Input buffer 2 check incorrect
F43
Input buffer 3 check incorrect
F44
Input buffer 4 check incorrect
Remedy:
Try to reset. If errors persist, contact Wintriss Tech Support for
assistance.
SmartPAC 2 Fault Messages
31* through 39*
41* through 44*
Chapter 7
1126800
page 397