GE B30 UR Series Instruction Manual page 472

Bus differential system
Hide thumbs Also See for B30 UR Series:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 52 of 60)
ADDR
REGISTER NAME
C615
...Repeated for Direct Output 8
C618
...Repeated for Direct Output 9
C61B
...Repeated for Direct Output 10
C61E
...Repeated for Direct Output 11
C621
...Repeated for Direct Output 12
C624
...Repeated for Direct Output 13
C627
...Repeated for Direct Output 14
C62A
...Repeated for Direct Output 15
C62D
...Repeated for Direct Output 16
C630
...Repeated for Direct Output 17
B
C633
...Repeated for Direct Output 18
C636
...Repeated for Direct Output 19
C639
...Repeated for Direct Output 20
C63C
...Repeated for Direct Output 21
C63F
...Repeated for Direct Output 22
C642
...Repeated for Direct Output 23
C645
...Repeated for Direct Output 24
C648
...Repeated for Direct Output 25
C64B
...Repeated for Direct Output 26
C64E
...Repeated for Direct Output 27
C651
...Repeated for Direct Output 28
C654
...Repeated for Direct Output 29
C657
...Repeated for Direct Output 30
C65A
...Repeated for Direct Output 31
C65D
...Repeated for Direct Output 32
Reset (Read/Write Setting)
C750
FlexLogic operand which initiates a reset
Control Pushbuttons (Read/Write Setting) (7 modules)
C760
Control Pushbutton 1 Function
C761
Control Pushbutton 1 Events
C762
...Repeated for Control Pushbutton 2
C764
...Repeated for Control Pushbutton 3
C766
...Repeated for Control Pushbutton 4
C768
...Repeated for Control Pushbutton 5
C76A
...Repeated for Control Pushbutton 6
C76C
...Repeated for Control Pushbutton 7
Force Contact Inputs/Outputs (Read/Write Settings)
C7A0
Force Contact Input
C800
Force Contact Output
Direct Inputs/Outputs (Read/Write Setting)
C880
Direct Device ID
C881
Direct I/O Channel 1 Ring Configuration Function
C882
Platform Direct I/O Data Rate
C883
Direct I/O Channel 2 Ring Configuration Function
C884
Platform Direct I/O Crossover Function
Direct Input/Output Commands (Read/Write Command)
C888
Direct Input/Output Clear Counters Command
Direct Inputs (Read/Write Setting) (32 modules)
C890
Direct Input 1 Device Number
B-60
RANGE
0 to 4294967295
0 to 1
0 to 1
x
0 to 2
State (96 items)
x
0 to 3
State (64 items)
1 to 16
0 to 1
64 to 128
0 to 1
0 to 1
0 to 1
0 to 16
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F300
---
1
F102
---
1
F102
---
1
F144
---
1
F131
---
1
F001
---
1
F126
kbps
64
F001
---
1
F126
---
1
F102
---
1
F126
---
1
F001
DEFAULT
0
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
1
0 (No)
64
0 (No)
0 (Disabled)
0 (No)
0
GE Multilin

Advertisement