GE B30 UR Series Instruction Manual page 439

Bus differential system
Hide thumbs Also See for B30 UR Series:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 19 of 60)
ADDR
REGISTER NAME
4114
PRT1 GOOSE Enabled
4115
PRT2 GOOSE Enabled
4116
PRT3 GOOSE Enabled
4117
IEC Communications Reserved (39 items)
413E
High Enet Traffic Function
413F
High Enet Traffic Events
4140
DNP Object 1 Default Variation
4141
DNP Object 2 Default Variation
4142
DNP Object 20 Default Variation
4143
DNP Object 21 Default Variation
4144
DNP Object 22 Default Variation
4145
DNP Object 23 Default Variation
4146
DNP Object 30 Default Variation
4147
DNP Object 32 Default Variation
Ethernet Switch (Read/Write Setting)
4148
Ethernet Switch IP Address
414A
Ethernet Switch Modbus IP Port Number
414B
Ethernet Switch Port 1 Events
414C
Ethernet Switch Port 2 Events
414D
Ethernet Switch Port 3 Events
414E
Ethernet Switch Port 4 Events
414F
Ethernet Switch Port 5 Events
4150
Ethernet Switch Port 6 Events
Ethernet Switch Actual Values (Read Only)
4151
Ethernet Switch MAC Address
4154
Ethernet Switch Port 1 Status
4155
Ethernet Switch Port 2 Status
4156
Ethernet Switch Port 3 Status
4157
Ethernet Switch Port 4 Status
4158
Ethernet Switch Port 5 Status
4159
Ethernet Switch Port 6 Status
415A
Switch Firmware Version
Communications Actual Values (Read Only)
4160
Modbus Available TCP/IP Connections
4161
DNP Available TCP/IP Connections
4162
IEC Available TCP/IP Connections
4163
MMS Available TCP/IP Connections
4164
PMU Available TCP/IP Connections
Simple Network Time Protocol (Read/Write Setting)
4168
Simple Network Time Protocol (SNTP) Function
4169
Simple Network Time Protocol (SNTP) Server IP
Address
416B
Simple Network Time Protocol (SNTP) UDP Port
Number
Clock (Read/Write Setting)
419F
Synchronizing Source
Clock (Read/Write Command)
41A0
Real Time Clock Set Time
Clock (Read/Write Setting)
41A2
SR Date Format
GE Multilin
RANGE
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
1 to 2
1 to 3
0 to 3
0 to 3
0 to 3
0 to 3
1 to 5
0 to 5
0 to 4294967295
1 to 65535
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
---
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0.00 to 99.99
0 to 4
0 to 2
0 to 2
0 to 5
0 to 4
0 to 1
0 to 4294967295
1 to 65535
0 to 3
0 to 235959
0 to 4294967295
B30 Bus Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
1
F102
---
1
F102
---
1
F001
---
1
F102
---
1
F102
---
1
F001
---
1
F001
---
1
F523
---
1
F524
---
1
F523
---
1
F523
---
1
F001
---
1
F525
---
1
F003
---
1
F001
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
---
F072
---
1
F134
---
1
F134
---
1
F134
---
1
F134
---
1
F134
---
1
F134
---
0.01
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F102
---
1
F003
---
1
F001
---
1
F623
---
1
F050
---
1
F051
DEFAULT
1 (Enabled)
1 (Enabled)
1 (Enabled)
0
0 (Disabled)
0 (Disabled)
2
2
0 (1)
0 (1)
B
0 (1)
0 (1)
1
0 (1)
3232235778
502
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
0
0 (Fail)
0 (Fail)
0 (Fail)
0 (Fail)
0 (Fail)
0 (Fail)
0
4
2
2
5
4
0 (Disabled)
0
123
0 (None)
0
0
B-27

Advertisement

Table of Contents
loading

Table of Contents