B

8.2 Capture View

On the Intruder Data Menu, click Capture View. This option allows the user to cap-
ture specified number of TISI's of data. The number of TISIs to be captured is
entered, then the maximum range is requested (see Overwrite). When the number
of TISIs have been captured, the updates are stopped. If the stop button on the but-
ton bar is clicked, the updates will also stop before completion of the specified num-
ber of TISIs.
9.

Viewing Cable Calibration Data

Cable calibrations are performed periodically by the TAS unit so that bearings may
be computed as accurately as possible. This option allows the user to view the
results of the most recent cable calibration and causes the cable calibrations to be
performed at an accelerated rate. Cable calibrations are normally spaced at 3
minute intervals, but this option causes the spacing between the end of one cable
calibration and the start of the next to be 10 seconds. An internal TAS unit variable
that displays messages on retries and/or errors is enabled.
A cable calibration sequence for a dual directional system requires about 8 seconds
to complete, so a new cable calibration summary will be displayed every 18 sec-
onds. To view the cable calibration data, View Data on the Cable Cal Menu (see
Figure
8).