Signal monitoring point
ZS (Function ID: 430001)
Element ID
8100021C21
8100021B61
8200021C22
8200021B62
8200021B23
8000021B66
8100021B67
8200021B68
8300021B63
8200021BB0
8200021BB2
8200021BB1
8300021B65
8400031C20
8400031B60
8300031B69
8500031C21
8500031B61
8600031C22
8600031B62
8300031B23
8400031B66
8500031B67
8600031B68
8700031B63
8300031BB0
8300031BB2
8300031BB1
8700031B65
8800041C20
8800041B60
8400041B69
8900041C21
8900041B61
8A00041C22
8A00041B62
8400041B23
8800041B66
8900041B67
8A00041B68
8B00041B63
8400041BB0
8400041BB2
8400041BB1
Name
Description
Z2S-BC
Z2S relay element operated (phase-BC)
Z2S-BCX
Z2S-BCX operated (phase-BC)
Z2S-CA
Z2S relay element operated (phase-CA)
Z2S-CAX
Z2S-CAX operated (phase-CA)
Z2S-OPT
Z2S operated (3-phases OR)
Z2S-OPT-AB
Z2S operated (phase-AB)
Z2S-OPT-BC
Z2S operated (phase-BC)
Z2S-OPT-CA
Z2S operated (phase-CA)
Z2S-ORX
Z2S-ORX operated (3-phases OR)
Z2STP_BLOCK
Z2S trip block signal
Z2S_ARCBLOCK
Autoreclose block signal for Z2S
Z2S_INST_OP
Z2S instantaneously operated
Z2S_ORX OP
Z2S operated before timer (3-phases OR)
Z3S-AB
Z3S relay element operated (phase-AB)
Z3S-ABX
Z3S-ABX operated (phase-AB)
Z3S-ARC-BLOCK
Autoreclose block by Z3S protection
Z3S-BC
Z3S relay element operated (phase-BC)
Z3S-BCX
Z3S-BCX operated (phase-BC)
Z3S-CA
Z3S relay element operated (phase-CA)
Z3S-CAX
Z3S-CAX operated (phase-CA)
Z3S-OPT
Z3S operated (3-phases OR)
Z3S-OPT-AB
Z3S operated (phase-AB)
Z3S-OPT-BC
Z3S operated (phase-BC)
Z3S-OPT-CA
Z3S operated (phase-CA)
Z3S-ORX
Z3S-ORX operated (3-phases OR)
Z3STP_BLOCK
Z3S trip block signal
Z3S_ARCBLOCK
Autoreclose block signal for Z3S
Z3S_INST_OP
Z3S instantaneously operated
Z3S_ORX OP
Z3S operated before timer (3-phases OR)
Z4S-AB
Z4S relay element operated (phase-AB)
Z4S-ABX
Z4S-ABX operated (phase-AB)
Z4S-ARC-BLOCK
Autoreclose block by Z4S protection
Z4S-BC
Z4S relay element operated (phase-BC)
Z4S-BCX
Z4S-BCX operated (phase-BC)
Z4S-CA
Z4S relay element operated (phase-CA)
Z4S-CAX
Z4S-CAX operated (phase-CA)
Z4S-OPT
Z4S operated (3-phases OR)
Z4S-OPT-AB
Z4S operated (phase-AB)
Z4S-OPT-BC
Z4S operated (phase-BC)
Z4S-OPT-CA
Z4S operated (phase-CA)
Z4S-ORX
Z4S-ORX operated (3-phases OR)
Z4STP_BLOCK
Z4S trip block signal
Z4S_ARCBLOCK
Autoreclose block signal for Z4S
Z4S_INST_OP
Z4S instantaneously operated