Basic information about the drive system
12.12 System sampling times and number of controllable drives
12.12.4

Default settings for the sampling times

When commissioning for the first time, the current controller sampling times (p0115[0]) are
automatically pre-set with factory setting values:
Table 12- 22 Factory settings
Construction type
Active Infeed
Booksize
Chassis
400 V / ≤ 300 kW
690 V / ≤ 330 kW
Chassis
400 V / > 300 kW
690 V / > 330 kW
Smart Infeed
Booksize
Chassis
400 V / ≤ 355 kW
690 V / ≤ 450 kW
Chassis
400 V / > 355 kW
690 V / > 450 kW
Basic Infeed
Booksize
Chassis
SERVO
Booksize
Chassis
Blocksize
VECTOR
Booksize
Chassis
400 V / ≤ 250 kW
Booksize
Chassis
400 V / ≤ 250 kW
Chassis
> 250 kW
690 V
Note
If a Power Module in blocksize format is connected to a Control Unit, the sampling times of
all vector drives are set according to the rules for Power Modules in blocksize format (only
250 µs or 500 µs possible).
916
Number
p0112
1
2 (Low)
1
2 (Low)
1
2 (Low)
1
0 (Expert)
1
1 (xLow)
1
2 (Low)
1
2 (Low)
1
2 (Low)
1
0 (Expert)
1
1 (xLow)
1
4 (High)
1
2 (Low)
1 to 6
3 (Standard)
1 to 6
1 (xLow)
1 to 5
3 (Standard)
1 to 3 only n_ctrl
3 (Standard)
1 to 6 only U/f
4 to 12
0 (Expert)
1 to 4 only n_ctrl
0 (Expert)
1 to 5 only U/f
1 (xLow)
1 to 6 only n_ctrl
0 (Expert)
p0115[0]
250 µs
250 µs
250 µs
375 µs (p0092 = 1)
400 µs (p0092 = 0)
250 µs
250 µs
250 µs
375 µs (p0092 = 1)
400 µs (p0092 = 0)
250 µs
2000 µs
125 µs
250 µs
125 µs
250 µs
500 µs
375 µs (p0092 = 1)
400 µs (p0092 = 0)
500 µs (p0092 = 1)
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
p1800
-
-
-
-
-
-
-
-
-
-
-
-
4 kHz
2 kHz
4 kHz
4 kHz
2 kHz
4 kHz
2 kHz
1.333 kHz
1.25 kHz
2 kHz
Drive functions