Siemens SINAMICS S120 Function Manual page 236

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Vector control
4.20 Flying restart
Overview of important faults and parameters (see SINAMICS S120/S150 List Manual)
Overview of important faults
• F07330
• F07331
Overview of important parameters
• p0352[0...n]
• p1082[0...n]
• p1200[0...n]
• p1202[0...n]
• p1203[0...n]
• r1204.0...14
• r1205.0...17
• p1780.11
• p1900
234
Flying restart: Detection current measured too low
Flying restart: Function not supported
Cable resistance
Maximum speed
Flying restart operating mode
Flying restart detection current
Flying restart search rate factor
CO/BO: Flying restart, V/f control status
CO/BO: Flying restart, vector control status
Motor model adaptation configuration
Fast flying restart with voltage model for induction machines
Motor data identification and rotating measurement
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3