Siemens SINAMICS S120 Function Manual page 674

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Communication
10.1 Communication according to PROFIdrive
Bit
Meaning
4
Brake test result
5
Brake test completed
6
External brake request
7
Current load sign
8...13
Reserved
14
Acceptance test SLP (SE) selected
15
Acceptance test mode selected
S_V_LIMIT_B
SLS speed limit with a 32-bit resolution with sign bit.
● The SLS speed limit is available in r9733[2].
● The SLS speed limit is standardized via p2000.
WARN_CODE
Display of the alarm code (see function diagram 8065).
FAULT_CODE
Display of the fault code (see function diagram 8060).
E_ZSW1 (status word for infeed)
See function diagram [2457].
Table 10- 37 Description of E_ZSW1 (status word for infeed)
Bit
Meaning
0
Ready to start
1
Ready
672
S_V_LIMIT_B = 4000 0000 hex ≐ speed in p2000
Remarks
1
0
1
0
Remarks
0
Test inactive
1
Test successful
0
Test error
1
Test run
0
Test incomplete
1
Close brake
0
Open brake
1
Negative sign
0
Positive sign
1
Acceptance test SLP (SE) selected
0
Acceptance test SLP (SE) deselected
1
Acceptance test mode selected
0
Acceptance test mode deselected
Ready to start
Not ready to start
Ready for operation
DC link pre-charged, pulses inhibited
Not ready for operation
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Parameter
r10234.4
r10234.5
r10234.6
r10234.7
r10234.14
r10234.15
Parameter
BO: r0899.0
BO: r0899.1
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading