Reset Energy Consumption Meter; Active Command Data Set; Active Drive Data Set (Dds) - Siemens MICROMASTER 440 Parameter Manual

0.12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Issue 01/06
P0040

Reset energy consumption meter

CStat:
CT
P-Group: INVERTER
Resets value of parameter r0039 (energy consumption meter) to zero.
Possible Settings:
0
No reset
1
Reset r0039 to 0
Dependency:
No reset until "P" is pressed.
r0050
CO: Active command data set
P-Group: COMMANDS
Displays currently selected and active command data set (CDS).
Possible Settings:
0
1st. Command data set (CDS)
1
2nd. Command data set (CDS)
2
3rd. Command data set (CDS)
Details:
See parameter P0810.
r0051[2]
CO: Active drive data set (DDS)
P-Group: COMMANDS
Displays currently selected and active drive data set (DDS).
Possible Settings:
0
1st. Drive data set (DDS)
1
2nd. Drive data set (DDS)
2
3rd. Drive data set (DDS)
Index:
r0051[0] : Selected drive data set
r0051[1] : Active drive data set
Details:
See parameter P0820.
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
Datatype: U16
Unit: -
Active: first confirm
QuickComm.: No
Datatype: U16
Unit: -
Datatype: U16
Unit: -
Parameter Description
Level
Min:
0
2
Def:
0
Max:
1
Level
Min:
-
2
Def:
-
Max:
-
Level
Min:
-
2
Def:
-
Max:
-
33