Command And Drive Datasets - Overview; Command Datasets (Cds) - Siemens MICROMASTER 440 Parameter Manual

0.12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Issue 01/06
2.3

Command and Drive Datasets - Overview

Command Datasets (CDS)

ParNo
Parameter text
P0700[3]
Selection of command source
P0701[3]
Function of digital input 1
P0702[3]
Function of digital input 2
P0703[3]
Function of digital input 3
P0704[3]
Function of digital input 4
P0705[3]
Function of digital input 5
P0706[3]
Function of digital input 6
P0707[3]
Function of digital input 7
P0708[3]
Function of digital input 8
P0719[3]
Selection of cmd. & freq. setp.
P0731[3]
BI: Function of digital output 1
P0732[3]
BI: Function of digital output 2
P0733[3]
BI: Function of digital output 3
P0800[3]
BI: Download parameter set 0
P0801[3]
BI: Download parameter set 1
P0840[3]
BI: ON/OFF1
P0842[3]
BI: ON reverse/OFF1
P0844[3]
BI: 1. OFF2
P0845[3]
BI: 2. OFF2
P0848[3]
BI: 1. OFF3
P0849[3]
BI: 2. OFF3
P0852[3]
BI: Pulse enable
P1000[3]
Selection of frequency setpoint
P1020[3]
BI: Fixed freq. selection Bit 0
P1021[3]
BI: Fixed freq. selection Bit 1
P1022[3]
BI: Fixed freq. selection Bit 2
P1023[3]
BI: Fixed freq. selection Bit 3
P1026[3]
BI: Fixed freq. selection Bit 4
P1028[3]
BI: Fixed freq. selection Bit 5
P1035[3]
BI: Enable MOP (UP-command)
P1036[3]
BI: Enable MOP (DOWN-command)
P1055[3]
BI: Enable JOG right
P1056[3]
BI: Enable JOG left
P1070[3]
CI: Main setpoint
P1071[3]
CI: Main setpoint scaling
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
1)
ParNo
Parameter text
X
P1074[3]
BI: Disable additional setpoint
X
P1075[3]
CI: Additional setpoint
X
P1076[3]
CI: Additional setpoint scaling
X
P1110[3]
BI: Inhibit neg. freq. setpoint
X
P1113[3]
BI: Reverse
X
P1124[3]
BI: Enable JOG ramp times
X
P1140[3]
BI: RFG enable
X
P1141[3]
BI: RFG start
X
P1142[3]
BI: RFG enable setpoint
X
P1230[3]
BI: Enable DC braking
X
P1330[3]
CI: Voltage setpoint
X
P1477[3]
BI: Set integrator of n-ctrl.
X
P1478[3]
CI: Set integrator value n-ctrl.
P1500[3]
Selection of torque setpoint
P1501[3]
BI: Change to torque control
X
P1503[3]
CI: Torque setpoint
X
P1511[3]
CI: Additional torque setpoint
X
P1522[3]
CI: Upper torque limit
X
P1523[3]
CI: Lower torque limit
X
P2103[3]
BI: 1. Faults acknowledgement
X
P2104[3]
BI: 2. Faults acknowledgement
X
P2106[3]
BI: External fault
X
P2200[3]
BI: Enable PID controller
X
P2220[3]
BI: Fixed PID setp. select Bit 0
X
P2221[3]
BI: Fixed PID setp. select Bit 1
X
P2222[3]
BI: Fixed PID setp. select Bit 2
X
P2223[3]
BI: Fixed PID setp. select Bit 3
X
P2226[3]
BI: Fixed PID setp. select Bit 4
X
P2228[3]
BI: Fixed PID setp. select Bit 5
X
P2235[3]
BI: Enable PID-MOP (UP-cmd)
X
P2236[3]
BI: Enable PID-MOP (DOWN-cmd)
X
P2253[3]
CI: PID setpoint
X
P2254[3]
CI: PID trim source
X
P2264[3]
CI: PID feedback
X
1) X = Parameters will be altered during data set
switchover (CDS) in the state "Run"
– = Parameters will be altered in the state "Ready" only
Parameters
1)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents