6.6

Communication Setup Menu

The Communication Setup Menu contains baud rate and Bilinx control settings.
* AutoBaud:
* Baud Rate:
AutoBaud
Turns on AutoBaud detection, which detects and adjusts the camera protocol and baud rate
to match that of the controller. Options: ON (default setting), OFF. ON automatically accepts
baud rates from 2400 to 57600.
Note: If stepping from 2400 to 57600 baud, you must first set the Baud Rate to 19200 for
AutoBaud to detect the higher baud rate.
Baud Rate
Manually sets the baud rate when AutoBaud is set to OFF. Options are 2400, 4800, 9600
(default setting), 19200, 38400, and 57600.
Bilinx
Activates Bilinx control communication. (Only available when not connected to a Bilinx data
interface unit.) Options: ON (default setting), OFF.
6.7

Alarm Setup

The Alarm Setup Menu contains alarm inputs, outputs and rules.
NOTICE!
The maximum number of Alarm Inputs is eight (8), available only on the Alarm and Washer
Pump Drive Card (MIC-ALM) (sold separately). This card is available for non-IR power supply
units (PSUs) only. See Section Figure 4.1
page 20 for the specific number of alarm Inputs and Outputs per PSU.
Bosch Security Systems, Inc.
Communication Setup
Exit...