Mounting Positions - Bosch MIC612 Installation Manual

Hide thumbs Also See for MIC612:
Table of Contents

Advertisement

MIC612 Thermal Camera
Figure 3.4 Typical corner mount (from left to right: Wall Mount Bracket (MIC-WMB), Shallow Conduit
Adapter (MIC-SCA), and Corner Mount Bracket (MIC-CMB))
3.2

Mounting Positions

CAUTION!
The upright unit can be mounted either with the camera ball up or down. To get the picture
the correct way for installation with the camera ball down, rotate the camera tilt axis 180°.
If the camera is mounted ball down, it is essential that the connector and base area of the
camera are completely sealed from water ingress. Any water getting into the connector is
liable to cause corrosion to the connector pins, leading to unreliable operation of the camera
unit. To prevent water penetrating the composite cable connector threads, seal the 25 mm
thread at final installation using PTFE tape. Alternately, a suitable sealant may be liberally
applied to the thread prior to final tightening.
MIC Series 612 cameras are designed to be mounted upright (straight up, 90°) or inverted
(straight down, 90°). See the figure below for the correct ways to mount the camera.
Figure 3.5 Mounting diagram: Correct ways (left) and Incorrect ways (right)
Number Description
1
2
3
4
Bosch Security Systems, Inc.
Correct way, Upright
Correct way, Inverted
Incorrect way, Inverted and canted
Incorrect way, inverted on top of pole
Installation Manual
Installation Overview | en
F.01U.249.416 | 1.1 | 2012.03
15

Advertisement

Table of Contents
loading

Table of Contents