68
en | ITS-DX4020-G Communicator Configuration
The main menu shows all current configuration settings first. An asterisk in front of a
configuration item indicates that its setting has been changed during the current session.
The content of the main menu constantly scrolls. When a user performs a new action, any
resulting response from the user interface appears at the end of the menu.
9.3.4

USB Option Menu

Refer to Table 9.5 for a description of the USB option menu items.
To see the USB option menu, refer to Figure 9.8, Page 67.
Option
1 Change password
2 Change log level
3 View log
4 Exit without Save
5 Restore Factory defaults
6 Save and Reboot
7 Upgrade Software
8 Change Basic parameters
9 Change Advanced parameters 9
Table 9.5 ITS-DX4020-G Menu Options
At a configuration screen, items are presented one at a time with the current value inside [ ]
brackets. If you press [Enter] without entering a new value, the current value is unchanged.
To go to a specific menu option, enter the appropriate menu item number and press [Enter].
F01U087835 | 02 | 2008.10
Press to
Description
Select
1
To change the login password, enter the old password first, and then
enter the new password twice. The second entry is to confirm the new
password.
Passwords must be 4-15 characters long, and they are case-sensitive.
0-9, A-Z, a-z, and special characters are allowed.
2
Change the debugging level shown on the View Log screen.
3
View the debugging log. Press any key to exit.
4
Return to the user interface login screen. All configuration changes that
were made are lost and are replaced with the default values.
5
Select Yes to restore all factory default configurations.
When prompted, remove the plug from the CONFIG jumper pins to
restart the ITS-DX4020-G.
6
Select Yes to save all configuration changes.
When prompted, remove the plug from the CONFIG jumper pins to
restart the ITS-DX4020-G.
7
Select this option to upgrade the software in the ITS-DX4020-G.
Refer to Section 9.4 Upgrading the ITS-DX4020-G Software, page 70.
8
To change a basic parameter:
1. Select the parameter.
2. Enter the desired value and press [Enter].
Refer to Table 9.6, Page 69 for basic parameters.
Select to change advanced parameters.
Refer to Table 9.7, Page 69 for advanced parameters.