Easy Series
Quick Reference
Refer to the following table for programmable features, shipping defaults, and recommended
programming that comply with the ANSI/SIA CP-01 False Alarm Reduction standard.
The system test button tests all points, all outputs, the control panel, and the communicator.
Refer to Section 8.1 Test the System, page 61 for more information.
Paragraph Number
Feature
in ANSI/SIA CP-01
4.2.2.1
Exit Time
4.2.2.2
Progress
Annunciation/
Disable for Silent
Exit
4.2.2.3
Exit Time Restart
4.2.2.5
Auto Stay Arm on
Unvacated
Premises
4.2.4.4
Exit Time and
Progress
Annunciation/
Disable for Remote
Arm
4.2.3.1
Entry Delay(s)
4.2.5.1
Abort Window for
Non-fire Zones
4.2.5.1
Abort Window Time
for Non-fire Zones
4.2.5.1.2
Abort Annunciation Required option
4.2.5.4.1
Cancel
Annunciation
4.2.6.1 and 4.2.6.2 Duress Feature
4.3.1
Cross Zoning
4.3.1
Programmable
Cross Zoning Time
4.3.2
Swinger Shutdown Required
4.3.2
Swinger Shutdown
Disable
Bosch Security Systems, Inc.
Requirement
Range
Required
For full or auto
(programmable)
arming: 45 sec to
2 min (255 sec max)
Allowed
Individual control
centers can be
disabled.
Required Option
For re-entry during
Exit Time
Required option
If no exit after full
(except for remote
arm
arm)
Allowed option (for
Can be disabled for
remote arm)
remote arm
Required
30 sec to 4 min
(programmable)
Required option
Can be disabled by
zone or zone type
Required
15 sec to 45 sec
(programmable)
Annunciate that no
alarm was
transmitted
Required option
Annunciate that a
Cancel was
transmitted
Allowed Option
No 1+ derivative of
another user code;
no duplicates of
other user codes
Required Option
Programming
needed
Allowed
Can program
For all non-fire
(programmable)
zones, shut down at
one or two faults
Allowed
For non-police
response zones
System Reference Guide
Agency Approvals and Requirements | en 115
Shipping
Recommended
Default
Programming
60 sec
60 sec
All control
All control centers
centers
enabled.
enabled.
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
30 sec
2
At least 30 sec
Enabled
Enabled (all
zones)
30 sec
2
At least 15 sec
Enabled
Enabled
Enabled
Enabled
Disabled
Disabled
Disabled
Enabled and two
or more zones
programmed
Per
Per walk path in
manufacturer
protected
premises
One fault
One fault
Enabled
Enabled (all
zones)
F01U087835 | 02 | 2008.10
1
2
2