36
en | Programming Access Options
4.3

Programming Keys

After you program a control panel using the Phone Menus or RPS, you can use a programming
key to transfer data from that control panel to another control panel. You can also use a
programming key to back up control panel data.
1.
2.
Figure 4.2 Programming Key Lock Positions
1
Send data from control panel to key
2
Send data from key to control panel
3.
4.
F01U087835 | 02 | 2008.10
If the system is on, turn it off.
Place the key's lock switch in the desired position. Refer to Figure 4.2.
Insert the key into the control panel board.
Auto Transfer: If Expert Programming Item Number 123 = 1 (refer to Programming
Key Auto Transfer in Section 5.2.2 System Programming Items, page 43), the
programming key automatically transfers data depending on the position of the lock
switch.
Manual Transfer: If Expert Programming Item Number 123 = 0, you must use the
Installer Menu to access the programming key.
The control center announces when data transfer is completed.
When the (√) LED flashes green, data transfer is successful.
If the (√) LED flashes red, the data transfer is unsuccessful. Remove and reinstall the key.
System Reference Guide
Easy Series
Bosch Security Systems, Inc.