Bosch ICP-EZM2 Easy Series System Reference Manual page 121

Easy series
Hide thumbs Also See for ICP-EZM2 Easy Series:
Table of Contents

Advertisement

Easy Series
Siren Wiring in a NF A2P Certified Installation
Use only sirens with backup battery. Sirens which require a primary voltage of 14.4V can be
powered by the optional module EZPS-FRA, or the auxiliary power supply IPP-PSU-2A5.
Bring the hold-on +12V through panel PO1, set it as the interior siren, as shown on the siren
installation guide. Depending on the current requirement of the siren battery, the hold-on +
voltage can be taken from the orange terminal, white terminal, +14.4V of the siren power
output of optional board EZPS-FRA, or one of the outputs of auxiliary power supply IPP-PSU-
2A5.
NOTICE!
i
In a NF A2P certified installation, the power supply used to feed the battery of the siren shall
not be used to feed the motion detectors.
Motion Detectors Wiring in a NF A2P Certified Installation
Power for motion detectors shall be separated from power for sirens. Power for motion
detectors can either come from the white terminal + and -, or by the optional board EZPS-FRA
when the number of motion detector requires separate power lines, or by the auxiliary power
supply IPP-PSU-2A5.
Panel Configuration in a NF A2P Certified Installation
Check that each parameter is in the range of authorized values for NF A2P certified
installations.
Current Chart in a NF A2P Type 2 Certified Installation
To meet the 36 hours of backup power, check that the current required by all the equipments
used in the system is lower than the backup current available:
Module
Easy Series Control Panel
Current for the panel: A
IUI-EZ1 Control Center (at least 1) 110 mA
Current on the option bus: B
Motion detector(s)
Siren(s)
(Autre)
Total aux current: C
Total A + B + C
Max backup current available, with a 17 AH battery (type
2, 36H)
Bosch Security Systems, Inc.
Max current in idle state: 465 mA (i.e. 270 mA of current for the panel , with one control
center)
Max current in alarm: 1000 mA (i.e. 675 mA of current for the panel, with one control
center)
Refer to the chart below.
Max Current in Idle State
I Max
85 mA
x1
x Qty
x Qty
x Qty
x Qty
System Reference Guide
Agency Approvals and Requirements | en 121
Max Current In Alarm State
Total
I Max
85 mA
160 mA
....mA
165 mA
....mA
...mA
...mA
465 mA
Total
x1
160 mA
...mA
xQty
....mA
x Qty
x Qty
x Qty
...mA
...mA
1000 mA
F01U087835 | 02 | 2008.10