Mounting the SICHARGE UC MastHood
No.
1
Transport the SICHARGE UC MastHood to the base area
2
Position the SICHARGE UC MastHood over the threaded rods on the base area
3
Open the maintenance door with the 8 mm triangular key
4
Loosen the 3 screws of the plastic cover and remove the cover
5
Guide any underground cables into the mounting base of the SICHARGE UC MastHood
6
Ensure that the SICHARGE UC MastHood is correctly aligned with the threaded rods of the base
area
7
Lower the SICHARGE UC MastHood onto the base area
8
Put the washers on the threaded rods
9
Screw the nuts onto the threaded rods
10
Align the SICHARGE UC MastHood on the threaded rods
11
Tighten the nuts with a torque of 550 Nm
12
Turn the lock nuts slightly away from the nuts
13
Apply a screw lock to the threaded rods